Eccentric Butterfly ValveHOME > PRODUCTS > Butterfly Valve > Eccentric Butterfly Valve

Butterfly Valve Flange Extension

发布时间:2022-05-20 点击人数:478次
INQUIRY NOW

Product Detail

Flanged Extension Butterfly Valve


 

Connection dimensions

Nominal

Diameter

External Dimension(reference)

Flange Dimension&Bolting Hole Diameter(Standard)

Max L

Min L

Stall L

H

H1

W

W1

0.6Mpa

1.0Mpa

1.6Mpa

DN

inch

D

D1

D2

n-d

D

D1

D2

n-d

D

D1

D2

n-d

50

2

210

170

190

80

309

180

200

140

110

88

4-14

165

125

99

4-18

165

125

99

4-18

65

2.5

210

170

190

95

337

180

200

160

130

108

4-14

185

145

118

4-18

185

145

118

4-18

80

3

210

170

190

98

347

180

200

190

150

124

4-18

200

160

132

8-18

200

160

132

8-18

100

4

240

200

220

114

373

180

200

210

170

144

4-18

220

180

156

8-18

220

180

156

8-18

125

5

240

200

220

128

405

180

200

240

200

174

8-18

250

210

184

8-18

250

210

184

8-18

150

6

240

200

220

139

440

270

280

265

225

199

8-18

285

240

211

8-22

285

240

211

8-22

200

8

280

230

255

174

612

270

280

320

280

254

8-18

340

295

266

8-22

340

295

266

12-22

250

10

280

230

255

215

639

270

280

375

335

309

12-18

395

350

319

12-22

405

350

319

12-26

300

12

310

260

285

245

747

380

420

440

395

363

12-22

445

400

370

12-22

460

400

370

12-26

350

14

310

260

285

270

802

380

420

490

445

413

12-22

505

460

429

16-22

520

460

429

16-26

400

16

360

300

330

305

991

450

470

540

495

463

16-22

565

515

480

16-26

580

515

480

16-30

450

18

360

300

330

325

1037

480

490

595

550

518

16-22

615

565

530

20-26

640

565

530

20-30

500

20

360

300

330

360

1127

480

490

645

600

568

20-22

670

620

582

20-26

715

620

582

20-33

600

24

420

350

385

445

1377

480

490

755

705

667

20-26

780

725

682

20-30

840

725

682

20-36

700

28

420

350

385

505

1496

640

660

890

810

772

24-26

895

840

794

24-30

910

840

794

24-36

800

32

470

400

435

560

1584

640

660

975

920

878

24-30

1015

950

901

24-33

1025

950

901

24-39

900

36

470

400

435

530

1676

750

860

1075

1020

978

24-30

1115

1050

1001

28-33

1125

1050

1001

28-39

1000

40

580

500

540

680

1760

850

900

1175

1120

1078

28-30

1230

1160

1112

28-36

1255

1160

1112

28-42

1200

48

630

550

590

795

2018

850

900

1405

1340

1295

32-33

1455

1380

1328

32-39

1485

1380

1328

32-48

1400

56

730

650

690

900

2363

1000

925

1630

1560

1510

36-36

1675

1590

1530

36-42

1685

1590

1530

36-48

1600

64

800

700

750

1100

2723

1000

925

1830

1760

1710

40-36

1915

1820

1750

40-48

1930

1820

1750

40-56

1800

72

850

750

800

1124

2844

1100

980

2045

1970

1918

44-39

2115

2020

1950

44-48

2130

2020

1950

44-56

2000

80

950

850

900

1292

3127

1100

980

2265

2180

2125

48-42

2325

2230

2150

48-48

2345

2230

2150

48-60

 

1)Place the flexible valve horizontally before installation, and it is not allowed to collide freely.

2)The face-to-face length is min dimension before out put, and extent to installment dimension(namely design length).

3)When the length between pipes is larger than installment length for flexible valve, please adjust the distance of pipes, but it is not allowed to extend the flexible valve to avoid the damage of flexible valve.

4)The butterfly valve maybe installed at any position. As perform the temperature compensation, put the yokes on both ends of axial pipes to avoide pulling out flexible pipes of valves, the yokes support force is calculated as below formula, and mustnt dismantle the yoke during operation.

5) When not applicable to temperature compensation, but to install and repair the valves conveniently,instead, it will be positoned by bolting and tightened by symmetrical converging force to avoid pulling out of flexible pipes, damage the flexible butterfly valve, pipeline devices and buildings, bolting diameters conform to flange bolting diameter, which bolt intensity and support test pressure and pipeline allowed to remove in case of operation.(additional bolts).

6) With precision machining and strict completion, dont extend and reduce the flexible butterfly valve on site freely. And it requests to get concentric at both ends and parallel flange face in pipelines.

7) The flexible section of valve is not allowed to install at corner or ends of pipelines.

8)Fixed bolt on flange should be symmetrical and clamped, shouldnt clamp fixed bolt of flange on single side...

9)Telescopic tube should be installed behind the valve.

10Telescopic part of telescopic valve shouldnt be installed on corner of pipe of end of pipe.


 


Main machine
PRODUCTS
ABOUT US
NEWS
FAQS
CONTACT US
Product
Fire-fighting Valve
Gate Valve&Knife Gate Valve
Butterfly Valve
Check Valve&Other Valves

No.45,Gongye South Road, Hi-tech Zone, Jinan City, Shandong Province, China.

0086-17615865918
0086-15169186751
kerrydang888
sales@jnbestone.com
SEND MAIL TO US

Focus on WeChat

Copyright©@2020 Jinan Bestone International Trade Co.,Ltd. support:@jinanweisou

Leave Your Message

Send